Two-zone house with a ground-coupled slab

Gypsum boardRcond=0.011 K/WMineral woolRcond=0.185 K/WOSB sheathingRcond=0.014 K/WBrick outer leafRcond=0.008 K/WOuter face → airRconv=0.012 K/WSteel lintelRlintel=0.42 K/WDouble glazingRwin=0.31 K/WInfiltration, 0.5 ACHqinf=185 WGround-floor slabRcond=0.6 K/WIntermediate floorRcond=0.09 K/WOpen stairwellqstair=240 WRoof → outdoor airRconv=0.14 K/WRoof → skyRrad=0.22 K/WGround-floor airCgf=2.1 MJ/KUpper-floor airCuf=1.8 MJ/KInternal gainsPint=600 WSolar gain through glazingqsol=850 WUpper-floor zone airTuf=23 °CGround-floor zone airTgf=21 °CBoard / woolWool / OSBOSB / brickOuter faceOutdoor airTout=-4 °CRoofTroof=8 °CSkyTsky=-15 °CDeep groundTgnd=10 °C